36. DELAYED RUPTURE OF FLEXOR POLLICIS LONGUS AFTER VOLAR PLATING FOR THE DISTAL RADIUS FRACTURE: 2 CASES REPORT

Dinh Ngoc Minh1, Le Gia Anh Thy1, Nguyen Viet Tan1, Nguyen The Tuan1, Pham Dinh Minh Duc1, Nguyen Van Thanh1, Vo Chau Hoang Long1
1 Hospital for Traumatology and Orthopaedics, Ho Chi Minh city

Main Article Content

Abstract

Background: Although rupture of the extensor digitorum longus or extensor pollicis longus is common after plating for the distal radius fractures, complication of flexor tendon rupture is very rare. Most of the current reports on flexor pollicis longus rupture after volar plating for distal radius fractures are related to the distal placement of the plate, second displacement, increasing the collision between the distal edge of the plate, screws and the flexor tendons will lead to tendon rupture.


Objective: To warn about the delayed rupture of flexor pollicis longus rupture after volar plating for the distal radius fracture, and to discuss the factors contributing to this complication, thereby recommending figure out how to prevent the complication.


Case report: Report 2 cases of delayed rupture of flexor pollicis longus after 6 months and 12 months respectively of volar butress plating and 3.5 mm screws for distal radius fractures. Results: The factors that caused flexor pollicis longus rupture in the two cases were related to the tendon impinging on the distal edge of the plate, and screws because the plate was placed distally and screws head protruded, and correction did not completely restore the bony anatomy. After 3 months of hardwere removal end to end sutures or tendon graftin, full movement of the thumb was restored.


Conclusion: When opening and internal fixation, it is necessary to completely restore the bony anatomy and place the plate proximal when possible. When there are symtoms such as tendon irritation, the surgeon shoud consider removing the implant as soon as possible after the bone union is achieved to avoid the complication of tendon rupture that make the treatment much more difficult.

Article Details

References

[1] Arora R, M Lutz, A Hennerbichler et al.,
Complications following internal fixation of
unstable distal radius fracture with a palmar
locking-plate. J Orthop Trauma, 2007. 21(5): p.
316-22. doi: 10.1097/BOT.0b013e318059b993.
[2] Ring D, JB Jupiter, J Brennwald et al.,
Prospective multicenter trial of a plate for dorsal
fixation of distal radius fractures. J Hand Surg
Am, 1997. 22(5): p. 777-84. doi: 10.1016/s0363-
5023(97)80069-x.
[3] Schnur DP, B Chang, Extensor tendon rupture
after internal fixation of a distal radius fracture
using a dorsally placed AO/ASIF titanium pi plate.
Arbeitsgemeinschaft für Osteosynthesefragen/
Association for the Study of Internal Fixation.
Ann Plast Surg, 2000. 44(5): p. 564-6. doi:
10.1097/00000637-200044050-00016.
[4] Bell JS, R Wollstein, ND Citron, Rupture of
flexor pollicis longus tendon: a complication
of volar plating of the distal radius. J Bone296
Joint Surg Br, 1998. 80(2): p. 225-6. doi:
10.1302/0301-620x.80b2.8351.
[5] Nunley JA, PR Rowan, Delayed rupture of the
flexor pollicis longus tendon after inappropriate
placement of the pi plate on the volar surface of
the distal radius. J Hand Surg Am, 1999. 24(6):
p. 1279-80. doi: 10.1053/jhsu.1999.1279.
[6] Duncan SF, AJ Weiland, Delayed rupture of the
flexor pollicis longus tendon after routine volar
placement of a T-plate on the distal radius. Am J
Orthop (Belle Mead NJ), 2007. 36(12): p. 669-70
[7] Klug RA, CM Press, MH Gonzalez, Rupture
of the flexor pollicis longus tendon after volar
fixed-angle plating of a distal radius fracture:
a case report. J Hand Surg Am, 2007. 32(7): p.
984-8. doi: 10.1016/j.jhsa.2007.05.006.
[8] Cross AW, CC Schmidt, Flexor tendon injuries
following locked volar plating of distal radius
fractures. J Hand Surg Am, 2008. 33(2): p. 164-
7. doi: 10.1016/j.jhsa.2007.11.011.
[9] Cho CH, KJ Lee, KS Song et al., Delayed rupture
of flexor pollicis longus after volar plating for a
distal radius fracture. Clin Orthop Surg, 2012.
4(4): p. 325-8. doi: 10.4055/cios.2012.4.4.325.
[10] Soong M, BE Earp, G Bishop et al., Volar
locking plate implant prominence and flexor
tendon rupture. J Bone Joint Surg Am, 2011.
93(4): p. 328-35. doi: 10.2106/jbjs.J.00193.
[11] Orbay JL, A Touhami, Current concepts in volar
fixed-angle fixation of unstable distal radius
fractures. Clin Orthop Relat Res, 2006. 445: p. 58-
67. doi: 10.1097/01.blo.0000205891.96575.0f.
[12] Berglund LM, TM Messer, Complications of
volar plate fixation for managing distal radius
fractures. J Am Acad Orthop Surg, 2009. 17(6):
p. 369-77. doi: 10.5435/00124635-200906000-
00005.
[13] Matityahu AM, SN Lapalme, A Seth et al., How
placement affects force and contact pressure
between a volar plate of the distal radius and the
flexor pollicus longus tendon: a biomechanical
investigation. J Hand Surg Eur Vol, 2013. 38(2):
p. 144-50. doi: 10.1177/1753193412453436.
[14] Drobetz H, E Kutscha-Lissberg, Osteosynthesis
of distal radial fractures with a volar locking
screw plate system. Int Orthop, 2003. 27(1): p.
1-6. doi: 10.1007/s00264-002-0393-x.
[15] Casaletto JA, D Machin, R Leung et al., Flexor
pollicis longus tendon ruptures after palmar
plate fixation of fractures of the distal radius. J
Hand Surg Eur Vol, 2009. 34(4): p. 471-4. doi:
10.1177/1753193408100964.