Objectives: To compare selected biochemical parameters in paired hemolyzed and non-hemolyzed specimens and discuss implications for laboratory quality at Tam Dao Regional Medical Center in 2026.
Methods: A descriptive cross-sectional study with paired-specimen comparisons included all eligible hemolyzed specimens collected between April 1 and October 1, 2026. Each hemolyzed specimen was paired with a non-hemolyzed specimen collected from the same patient within 30 minutes after hemolysis was detected. Glucose, creatinine, aspartate aminotransferase (AST), alanine aminotransferase (ALT), potassium, and total bilirubin were assessed. Data were analyzed using Microsoft Excel.
Results: The study included 21 specimen pairs. Hemolysis grades I, II, and III accounted for 52.38%, 33.33%, and 14.29% of pairs, respectively. Glucose and creatinine tended to be slightly lower, ALT higher, and total bilirubin lower in hemolyzed specimens. AST and potassium showed the largest increases, with differences tending to increase across hemolysis grades. Reported p-values indicated statistically significant differences for AST in all three grades, potassium in grades I and II, creatinine in grade I, and total bilirubin in grade III. The potassium difference in grade III was not statistically significant.
Conclusion: In this small, single-center paired-specimen study, hemolyzed specimens showed higher AST and potassium measurements than non-hemolyzed specimens. These findings support attention to specimen quality and analyte-specific reporting decisions but do not establish validated rejection thresholds or the effectiveness of quality-improvement interventions.