1. Background: Coronary bifurcation lesions remain a challenge for interventional cardiologists. While plaque shift is often blamed for side branch (SB) occlusion, carina shift plays a dominant role in many cases, especially in lesions with high lipid content.
2. Case presentation: We report a 75-year-old male presenting with NSTEMI and a Medina 1:1:0 LM-LAD lesion. Despite low predictive risk scores (V-RESOLVE 0, COBIS II low risk), acute LCx occlusion (no-flow) occurred immediately after jailed wire removal.
3. Intervention & Outcome: Pre-procedural NIRS-IVUS revealed a massive lipid core with a maxLCBI4 of 904 at the confluence. The mechanism of occlusion was suspected to involve dynamic carina shift, exacerbated by the high lipid burden. The jailed wire was hypothesized to provide a "spacer effect" maintaining flow; its removal caused the carina to recoil and obstruct the LCx ostium. Successful recanalization was achieved, and TIMI grade 3 flow was restored. The patient remained event-free during post-discharge follow-up.
4. Conclusion: This case highlights the importance of NIRS-IVUS in assessing plaque characteristics. The risk of dynamic carina shift should be considered even with low 2D predictive risk scores, emphasizing the need for meticulous troubleshooting upon jailed wire removal in bifurcation PCI.