Articles Tập 67 Số CĐ16 09/11/2026

EVALUATION OF THE DIAGNOSTIC ACCURACY AND SAFETY OF CT-GUIDED TRANSTHORACIC BIOPSY FOR PULMONARY NODULES ≤1 CM

Nguyen Thi Hong Nhung, Doan Tien Luu, Nguyen Ngoc Cuong
DOI: 10.52163/yhc.v67iCD16.7024
52 Views
0 Downloads
Abstract

Objective: To evaluate the diagnostic accuracy and safety of CT-guided transthoracic biopsy for pulmonary nodules ≤1 cm. Materials and Methods: A cross-sectional descriptive study combining retrospective and prospective data on 25 patients with pulmonary nodules ≤1 cm who underwent biopsy at the Center of Diagnostic Imaging and Interventional Radiology, Hanoi Medical University Hospital from May 2024 to May 2026. Biopsy results were compared with the final diagnosis based on histopathology, surgery, or imaging follow-up. Results: The rate of determining the nature of the lesions was 44%, of which malignant lesions accounted for 40%. Solid lesions were predominant (76%) and most were located near the pleura (<3 cm). Pneumothorax was the most common complication, in addition to hemoptysis and pulmonary hemorrhage, mostly mild. No statistically significant association was found between needle depth, insertion angle, and complications (p > 0.05). Conclusion: CT-guided transthoracic biopsy is a feasible and relatively safe method for small pulmonary nodules ≤1 cm. Although the rate of final diagnosis is still limited, it contributes significantly to guiding follow-up or treatment for patients.

References
[1]
1. Jonas DE, Reuland DS, Reddy SM, et al. Screening for Lung Cancer With Low-Dose Computed Tomography: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force. JAMA. 2021;325(10):971-987. doi:10.1001/jama.2021.0377 Google Scholar
[2]
2. MacMahon H, Naidich DP, Goo JM, et al. Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017. Radiology. 2017;284(1):228-243. doi:10.1148/radiol.2017161659 Google Scholar
[3]
3. Choi SH, Chae EJ, Kim JE, et al. Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1 cm: analysis of outcomes of 305 procedures from a tertiary referral center. AJR Am J Roentgenol. 2013;201(5):964-970. doi:10.2214/AJR.12.10156 Google Scholar
[4]
4. Tian P, Wang Y, Li L, Zhou Y, Luo W, Li W. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing. J Thorac Dis. 2017;9(2):333-343. doi:10.21037/jtd.2017.02.16 Google Scholar
[5]
5. Ahn JH, Jang JG. Initial Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy of Lung Lesions Performed by a Pulmonologist. J Clin Med. 2019;8(6):821. doi:10.3390/jcm8060821 Google Scholar
[6]
6. Heerink WJ, de Bock GH, de Jonge GJ, Groen HJM, Vliegenthart R, Oudkerk M. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. Eur Radiol. 2017;27(1):138-148. doi:10.1007/s00330-016-4357-8 Google Scholar
[7]
7. Aktas AR, Gozlek E, Yazkan R, et al. Transthoracic biopsy of lung masses: Non technical factors affecting complication occurrence. Thorac Cancer. 2015;6(2):151-158. doi:10.1111/1759-7714.12156 Google Scholar