ACCURACY OF INTRAORAL PHOTOGRAMMETRY IN DIGITAL IMPRESSIONS FOR FULL-ARCH IMPLANT REHABILITATION: AN IN VITRO STUDY

Nguyen Thi Khanh Ha, Tran Duy Quan, Phi Thi Hung, Nguyen Van Ti, Nguyen Thien Nhan, Nguyen Thi Le Quyen, Nguyen Tran Bao Linh, Bui Ngoc Huyen Trang, Truong Nhut Khue
DOI: 10.52163/yhc.v67iCD15.6793
84 Views
0 Downloads
Abstract

Objectives: To evaluate the accuracy of intraoral photogrammetry in digital impressions for full-arch implant rehabilitation.

Subjects and methods: An in vitro study was conducted on a monolithic 3D-printed edentulous maxillary model equipped with 4 digital analogs. A reference scan was obtained with a 3Shape D2000 laboratory scanner, and 10 test scans were acquired using a Shining 3D Aoralscan Elite intraoral scanner with coded scan body accessories. The *.stl files were superimposed and analyzed using CloudCompare software to calculate linear deviations (Δx, Δy, Δz, ΔEUC) and angular deviations. Trueness (n = 10) and precision (n = 45) were evaluated and compared against reference thresholds using a one-sample t-test with a significance level of p < 0.05.

Results: Regarding trueness, the mean overall linear deviation (ΔEUC) was 87.71 ± 3.42 µm, and the angular deviation was 0.59 ± 0.00 degrees. Regarding precision, the ΔEUC was 8.25 ± 3.94 µm, and the angular deviation was 0.05 ± 0.02 degrees. Deviations in the x and y axes, ΔEUC, and angular deviations were significantly lower than the clinically acceptable thresholds (p < 0.001). The z-axis deviation (56.42 ± 4.54 μm) exceeded the 50 μm threshold (p = 0.002).

Conclusion: This technology demonstrates high accuracy in digital impressions for full-arch implant rehabilitation. Most deviations were within clinically acceptable limits, except for the z-axis deviation, which exceeded the reference threshold. Further studies are needed to standardize the protocol and improve clinical applicability.

References
[1]
[1] Manzella C, Bignardi C, Burello V et al. Method to improve passive fit of frameworks on implant-supported prostheses: an in vitro study. J Prosthet Dent, 2016, 116 (1): 52-58. doi: 10.1016/j.prosdent.2016.01.006. Google Scholar
[2]
[2] Paratelli A, Vania S, Gómez-Polo C et al. Techniques to improve the accuracy of complete arch implant intraoral digital scans: a systematic review. J Prosthet Dent, 2023, 129 (6): 844-854. doi: 10.1016/j.prosdent.2021.08.018. Google Scholar
[3]
[3] Pozzi A, Carosi P, Gallucci G.O et al. Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: an in vivo prospective comparative study. Clin Oral Implants Res, 2023, 34 (10): 1106-1117. doi: 10.1111/clr.14141. Google Scholar
[4]
[4] Brakoč J, Todorović A, Mangano F.G et al. Accuracy of intraoral photogrammetry versus direct digital implant impressions in the fully edentulous lower jaw: an in vitro study. J Dent, 2025, 156: 105654. doi: 10.1016/j.jdent.2025.105654. Google Scholar
[5]
[5] Pachiou A, Rachiotis I, Ioannidis A et al. Materials and techniques for splinting scan bodies: a scoping review. Materials, 2026, 19 (4): 664. doi: 10.3390/ma19040664. Google Scholar
[6]
[6] Revilla-León M, Cascos R, Barmak A.B et al. Clinical accuracy of complete arch implant scans recorded by using a noncalibrated splinting technique, intraoral photogrammetry, and extraoral photogrammetry with snap-on markers. J Prosthet Dent, 2026, 135 (1): 108.e1-108.e7. doi: 10.1016/j.prosdent.2025.09.012. Google Scholar
[7]
[7] Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res, 1994, 5 (1): 30-36. doi: 10.1034/j.1600-0501.1994.050104.x. Google Scholar
[8]
[8] Revilla-León M, Cascos R, Barmak A.B et al. Registration accuracy of soft tissue information scan captured using an intraoral scanner and implant position scan recorded using extraoral and intraoral photogrammetry systems. J Prosthet Dent, 2026, 135 (3): 597-604. doi: 10.1016/j.prosdent.2025.04.037. Google Scholar
[9]
[9] Pozzi A, Laureti A, Tawil I et al. Intra oral photogrammetry: trueness evaluation of novel technology for implant complete-arch digital impression in vitro. Clin Implant Dent Relat Res, 2025, 27 (3): e70049. doi: 10.1111/cid.70049. Google Scholar
[10]
[10] Tasakou A, Tooulia A, Kanellos I et al. Intraoral photogrammetry for full-arch implant scanning: a literature review. J Dent, 2026, 167: 106468. doi: 10.1016/j.jdent.2026.106468. Google Scholar