Articles Vol. 65 No. CĐ 2 - NCKH 08/04/2024

31. AUGMENTATION PLATE AND BONE GRAFTING TO TREAT FEMORAL SHAFT NONUNION INITIALLY FIXED BY CLOSED INTRAMEDULLARY NAILING AND LOCKING - ONE CASE REPORT

Le Phuc1,2
1 Saigon ITO Hospital
2 Bệnh viện Saigon ITO thành phố Hồ Chí Minh
Corresponding author: leanhuyen108@gmail.com
DOI: 10.52163/yhc.v65iCD2.1035
14 Views
15 Downloads
Abstract

Objective: Introduce an effective treatment for the femoral shaft nonunion, after failure of closed intramedullary nailing and locking.

Method: Descriptive one - case report of femoral shaft nonunion due to failure of closed intramedullary nailing and locking. Patient was reoperated: debridement of nonunion, cancellous autograft harvested from iliac wing, augmentation plate with 6 screws. No hardware removal of anterior surgery.

Results: Postoperative follow-up after 1,3,6 months. Bone healing registered in the end of 3th month.Walking and light running were performable.Hardwares removal was carried out after 30 months. The last follow-up at 33th month (since augmentation plate and bone graft surgery): good bone healing, range of motion (hip, knee,ankle) well recovered. Normal walking, running, sports practices well regained. Harris score was 98/100.

Conclusion: Treatment for femoral shaft nonunion due to failure of initially closed intramedullary nailing and locking by debridement, no removal of anterior hardware, cancellous autograft and augmentation plate resumed effective, easy to perform, good reference for orthopaedic practice.

References
[1]
Choi YS, Kim KS, Plate Augmentation Leaving Google Scholar
[2]
the Nail in Situ and Bone Graft for Non-Union Google Scholar
[3]
of Femoral Shaft Fractures. Int Orthop, 2005, Google Scholar
[4]
, 287-290. Google Scholar
[5]
Hồ Văn Thạnh, Đánh giá kết quả điều trị khớp Google Scholar
[6]
giả thân xương đùi đã đóng đinh nội tủy bằng Google Scholar
[7]
nẹp vít tăng cường và ghép xương tự thân; Luận Google Scholar
[8]
văn bác sĩ chuyên khoa II, Đại học Y Khoa Phạm Google Scholar
[9]
Ngọc Thạch Thành phố Hồ Chí Minh, 2020. Google Scholar
[10]
Lai PJ, Hsu YH, Chou YC et al., Augmentative Google Scholar
[11]
Antirotational Plating Provided a Significantly Google Scholar
[12]
Higher Union Rate than Exchanging Reamed Google Scholar
[13]
Nailing in Treatment for Femoral Shaft Aseptic Google Scholar
[14]
Atrophic Nonunion-Retrospective Cohort Study. Google Scholar
[15]
BMC Musculoskelet Disord; 2019, 20, 127. Google Scholar
[16]
Nadkarni B, Srivastav S, Mital V et al., Use Google Scholar
[17]
of Locking Compression Plates for Long Google Scholar
[18]
Bone Nonunions without Removing Existing Google Scholar
[19]
Intramedullary Nail: Review of Literature and Google Scholar
[20]
Our Experiences. J. Trauma Inj Infect Crit Care, Google Scholar
[21]
,65,482-486. Google Scholar
[22]
Nguyễn Ngọc Long, Đánh giá kết quả điều trị Google Scholar
[23]
khớp giả vô trùng thân xương đùi sau kết hợp Google Scholar
[24]
xương ở người trưởng thành; Luận án Chuyên Google Scholar
[25]
khoa II, Đại học Y Dược Thành phố Hồ Chí Google Scholar
[26]
Minh, 2005. Google Scholar