Bài báo khoa học Tập 67 Số English Version No 2, 2026 27/11/2026

RIGHT VERSUS LEFT TRANSPERITONEAL LAPAROSCOPIC LIVING DONOR NEPHRECTOMY: EXPERIENCE WITH PARTIAL CLAMPING OF THE INFERIOR VENA CAVA THROUGH A MINI-SUBCOSTAL INCISION

Pham Tai An, Nguyen Phu Viet, Nguyen Nhat An, Cao Quyet Thang, Nguyen Anh Tuan
DOI: 10.52163/yhc.v67iE2.7094
0 Lượt xem
0 Lượt tải xuống
Tóm tắt

Objectives: To compare vascular anatomy, surgical techniques, and perioperative outcomes between right and left transperitoneal laparoscopic living donor nephrectomy.

Materials and methods: This single-center prospective observational study included 78 consecutive living donors who underwent transperitoneal laparoscopic donor nephrectomy at Military Hospital 103 between June 2025 and January 2026: 43 left and 35 right nephrectomies.

Results: The right renal vein was significantly shorter than the left (18.31 ± 7.23 vs. 62.76 ± 13.86 mm; p < 0.001). All left kidneys had at least two renal vein tributaries, whereas 85.7% of right kidneys had none (p < 0.001). Median operative time was 112 min for right and 111 min for left nephrectomy (p = 0.432). In multivariable analyses, right nephrectomy was associated with a 0.68-min shorter warm ischemia time (95% confidence interval [CI], −1.12 to −0.23; p = 0.003) and a 1.68-cm longer extraction incision (95% CI, 1.05 to 2.32; p < 0.001). No statistically significant between-group differences were detected in blood loss or intraoperative or postoperative complication rates.

Conclusion: In this single-center series, right transperitoneal laparoscopic living donor nephrectomy with partial clamping of the inferior vena cava through a mini-subcostal incision was feasible. It was associated with shorter warm ischemia time and a longer extraction incision than left nephrectomy; no statistically significant differences in perioperative complication rates were detected.

Objectives: To compare vascular anatomy, surgical techniques, and perioperative outcomes between right and left transperitoneal laparoscopic living donor nephrectomy.

Materials and methods: This single-center prospective observational study included 78 consecutive living donors who underwent transperitoneal laparoscopic donor nephrectomy at Military Hospital 103 between June 2025 and January 2026: 43 left and 35 right nephrectomies.

Results: The right renal vein was significantly shorter than the left (18.31 ± 7.23 vs. 62.76 ± 13.86 mm; p < 0.001). All left kidneys had at least two renal vein tributaries, whereas 85.7% of right kidneys had none (p < 0.001). Median operative time was 112 min for right and 111 min for left nephrectomy (p = 0.432). In multivariable analyses, right nephrectomy was associated with a 0.68-min shorter warm ischemia time (95% confidence interval [CI], −1.12 to −0.23; p = 0.003) and a 1.68-cm longer extraction incision (95% CI, 1.05 to 2.32; p < 0.001). No statistically significant between-group differences were detected in blood loss or intraoperative or postoperative complication rates.

Conclusion: In this single-center series, right transperitoneal laparoscopic living donor nephrectomy with partial clamping of the inferior vena cava through a mini-subcostal incision was feasible. It was associated with shorter warm ischemia time and a longer extraction incision than left nephrectomy; no statistically significant differences in perioperative complication rates were detected. These findings do not establish equivalent safety.

These findings do not establish equivalent safety.

Tài liệu tham khảo
[1]
[1] Broudeur L, Karam G, Chelghaf I, et al. Feasibility and safety of laparoscopic living donor nephrectomy in case of right kidney and multiple-renal artery kidney: a systematic review of the literature. World J Urol. 2020;38(4):919-927. doi:10.1007/s00345-019-02821-8. Google Scholar
[2]
[2] Kumar A, Chaturvedi S, Gulia A, et al. Laparoscopic live donor nephrectomy: comparison of outcomes right versus left. Transplant Proc. 2018;50(8):2327-2332. doi:10.1016/j.transproceed.2018.03.034. Google Scholar
[3]
[3] Nguyen Viet Hai, Tran Van Linh, Nguyen Thu Ha, et al. Results of transperitoneal laparoscopic donor nephrectomy: a 500-case series at 108 Military Central Hospital (in Vietnamese). Journal of 108 - Clinical Medicine and Pharmacy. 2026;21(6). doi:10.52389/ydls.v21i6.3099. Google Scholar
[4]
[4] Cao Minh Phuc, Le Nguyen Vu, Hoang Long, Nguyen Quang Nghia. Transperitoneal laparoscopic donor nephrectomy in living donors: comparison of outcomes between single and multiple renal arteries (in Vietnamese). Vietnam Medical Journal. 2025;554(3):38-42. doi:10.51298/vmj.v554i3.15724. Google Scholar
[5]
[5] Tyagi V, Singh M, Pahwa M, et al. Right laparoscopic donor nephrectomy: a large-volume, single-center experience. Exp Clin Transplant. 2021;19(3):217-223. doi:10.6002/ect.2020.0346. Google Scholar
[6]
[6] Zaytoun O, Elsawy M, Ateba K, et al. Laparoscopic donor nephrectomy: technique and outcome, a single-center experience. Afr J Urol. 2021;27:151. doi:10.1186/s12301-021-00254-7. Google Scholar
[7]
[7] Le Nguyen Vu, Nguyen Minh An. Comparison of actual anatomy in living kidney donors with computed tomography findings (in Vietnamese). Vietnam Medical Journal. 2023;532(1B). doi:10.51298/vmj.v532i1B.7506. Google Scholar
[8]
[8] Shrestha KK, Shrestha PC, Pradhananga S, Lama S. Mean warm ischemia time among kidney transplant patients in a tertiary care centre: a descriptive cross-sectional study. JNMA J Nepal Med Assoc. 2023;61(262):519-521. doi:10.31729/jnma.8190. Google Scholar
[9]
[9] Liu Y, Huang Z, Chen Y, et al. Staplers or clips? A systematic review and meta-analysis of vessel controlling devices for renal pedicle ligation in laparoscopic live donor nephrectomy. Medicine (Baltimore). 2018;97(45):e13116. doi:10.1097/MD.0000000000013116. Google Scholar
[10]
[10] US Food and Drug Administration. Class 2 device recall: Weck Hem-o-lok ML polymer ligating clips. Recall No. Z-1096-06. Posted June 9, 2006. Available from: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfres/res.cfm?id=45799. Google Scholar